banner

 

Obstruction light for chimney

 

cheminee.gif 
 Height Night only operation Day and night operation
Up to 45m

 

3 to 4 low intensity lights placed 1,5 up to 3m below the top to avoid smokes to hide the lights 

 

 
Above 45m

Additional low intensity lights at intermediate levels. At the top low intensity or red medium intensity.

 

3 to 4 white medium intensity placed 1,5 up to 3m below the top to avoid smokes to hide the lights 

 

Above 150m, 3 to 4 high intensity lights placed 1,5 up to 3m below the top and at intermediate level(s) every 150m.

obsta histim sti histi.jpg 

Low intensity OBSTA HI STI 110VAC up to 240VAC and OBSTA STI 24VCC & 48VCC. More info 

icon OBSTA HI STI 110VAC à 240VAC

 icon OBSTA STI 24VCC & 48 VCC

icon OBSTA HI STIM 230VAC

In option junction and monitoring box

icon Accessories for installation

 

 

 armoire_energie.gif

Battery cabinet with 12 hours of autonomy in case of power failure and photocell. To be used with 24VCC or 48VCC OBSTA lights 

 icon 48V & 24V battery cabinet and photocell